Projects & results · Holliday Process Solutions
Holliday Process Solutions
Projects & results

Twenty years of panels that are still running.

The proof is not the brochure. It is compression stations that stopped losing instruments, metering skids that bill accurately through storm season, and telecom panels that installed in one visit. Here is a sample of the work and what it produced.

20+years protecting instrumentation on major US pipelines
$100M+of equipment, infrastructure and instruments protected
8 yrswithout a protected-instrument failure at one operator, as reported by the customer
<5 nsSPD response on HPS-protected circuits, manufacturer rated
365days a year of technical support to field personnel
Recent work

Built here. Running there.

A few of the panels, skids and shelters from the HPS shop. See the full gallery →

Results our clients report

Measured in equipment that did not fail.

Every one of these is a site that was losing equipment or downtime before HPS, and stopped afterward. Client statements as provided to HPS; names shown with permission.

$100kper week in losses before HPS

Eight compression sites, one grounding audit

Shell Pipeline was losing instrumentation and downtime at eight compression sites every storm season. HPS performed a grounding and bonding audit, corrected the ground grid, and installed coordinated surge protection on I/O, field instruments and 120 VAC. No loss has been reported since.

  • Grounding & bonding audit
  • Coordinated SPDs on I/O, instruments and AC
  • Eight sites, one standard
Shell Pipeline
8 yrswithout a single equipment failure

Thousands of transmitters, zero failures

Kinder Morgan protects thousands of transmitters and field instruments with HPS surge protection and panels. In eight years of doing business together, not a single protected instrument has failed.

  • Transmitter and field-instrument protection
  • Program-wide standard
  • Continuous supply and support
Kinder Morgan
$100k+of equipment protected, no downtime

I/O, instruments and 120 VAC

Williams Pipeline and Energy Transfer sites run HPS protection across PLC I/O, field instruments and 120 VAC control power. Hundreds of thousands of dollars of equipment protected with no equipment loss and no downtime reported.

  • PLC I/O protection
  • Field-instrument protection
  • 120 VAC control-power protection
Williams Pipeline · Energy Transfer
$1.5Mof equipment at three facilities

The only facilities with no storm loss

We Energies started with three facilities and $1.5 million of equipment under HPS protection. During a major storm, those were the only facilities with no equipment loss and no downtime. HPS protection is now written into their standard for all installations.

  • Three facilities, then the whole standard
  • Storm-tested
  • Specified for all new installations
We Energies
Recent programs

What left the shop in 2024 and 2025.

From the HPS shop. Site and customer names withheld; every one of these was built to the owner's standard, tested with the customer, and documented in AutoCAD.

Skid-mounted equipment shelter staged for delivery
Skid shelters · 2024

Plug-and-play shelters for a pipeline program

Equipment shelters on skids, pre-wired with power, protection and telecom, set and energized in a day.

Open equipment shelter showing wired interior
Shelter interior · 2024

Wired, labeled and tested before it ships

Every conductor numbered to the schematic, every point checked, torque marks on every lug.

Panelboard with motor-starter enclosure
Power distribution · 2024

Panelboard and motor-starter package

Branch panelboard and NEMA motor-starter enclosure, wired, labeled and tested as one package.

Skid-mounted switch rack with sun shield
Switch racks · 2024

Skid-mounted switch rack with sun shield

Galvanized skid, free-standing rack, junction boxes and conduit pre-run, shaded for the Texas sun.

Skid-mounted enclosure shelters staged for delivery
Enclosure shelters · skids

Shelters with sun shields, staged for delivery

Skid-mounted enclosure shelters, pre-wired and tested, ready to set and connect on site.

DC UPS enclosure with battery bank
Backup power

DC UPS with battery monitoring

Keeps RTUs, radios and instruments online through outages and brownouts, integrated with the site's surge protection.

Open control enclosure on a pallet
Custom enclosures

Laid out for the technician

Segregated ducts, marshalled terminals, service clearances, and a drawing that matches what is in the box.

RTU panel with redundant controllers
RTU systems

Redundant controllers, marshalled I/O

Hot-standby RTU controllers with managed industrial Ethernet, built to the owner's template.

Quality, on purpose

How a panel earns the HPS nameplate.

Quality is a sequence of checks with a name on each one, not a slogan. This is the sequence every panel goes through before it is crated.

01

Drawing review

Layout, schematics and BOM checked against the owner's standard and UL 508A before anything is cut. Calculations attached: loads, voltage drop, SCCR, thermal.

02

Build to the released set

Every wire numbered from the schematic, every device tagged per ISA-5.1, ducts filled to the limit on the drawing and no further.

03

Point-to-point check

A technician who did not wire the panel rings out every conductor against the drawing and signs the checklist.

04

Torque and label audit

Terminals torqued to specification and marked. Nameplate, warning labels and wire markers verified against the label schedule.

05

Factory acceptance test

Powered up, I/O simulated, communications proven, alarms exercised, with your engineer in the room or on a live camera. Red-lines captured once.

06

Documentation and ship

As-built drawings in AutoCAD, test record, photos of the finished panel and a serial number that follows it for life. Crated, insured, tracked.

UL 508AUL 12.12.01 · CLASS I DIV 2UL 1203NFPA 79ISA-5.1 TAGGINGFAT RECORD ON EVERY PANELAS-BUILTS IN AUTOCAD
Industries

Where the panels go.

Natural gas transmission and gathering, refining and petrochemical, water and wastewater, power utilities, pulp and paper, and now AI data centers. Engineering and construction firms specify HPS on behalf of pipeline, utility and process owners.

Natural gas & pipelines

Compression, metering, dehydration, well sites and mainline valves. Twenty years on the biggest systems in the country.

Refining & petrochemical

Instrument protection, PLC and RTU panels and Class I Division 2 enclosures for process units and tank farms.

Water & wastewater

Lift stations, treatment control, telemetry and solar-powered remote sites.

Power utilities

Substation and generation instrumentation protection that is written into a utility's installation standard.

AI data centers

Cooling plant, CDU, generator, fuel, water and perimeter panels for the Texas buildout. See the campus →

Telecom & remote sites

Radio, cellular and satellite integration with NexxtGen field crews and connectivity.

Your site next

Tell us what keeps failing.

Send the site, the equipment and the last three failures. We will tell you whether it is grounding, protection, power or all three, and what it costs to fix.